Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53.565
Filtrar
1.
Eur Radiol Exp ; 8(1): 49, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38622388

RESUMO

BACKGROUND: Automatic exposure control (AEC) plays a crucial role in mammography by determining the exposure conditions needed to achieve specific image quality based on the absorption characteristics of compressed breasts. This study aimed to characterize the behavior of AEC for digital mammography (DM), digital breast tomosynthesis (DBT), and low-energy (LE) and high-energy (HE) acquisitions used in contrast-enhanced mammography (CEM) for three mammography systems from two manufacturers. METHODS: Using phantoms simulating various breast thicknesses, 363 studies were acquired using all available AEC modes 165 DM, 132 DBT, and 66 LE-CEM and HE-CEM. AEC behaviors were compared across systems and modalities to assess the impact of different technical components and manufacturers' strategies on the resulting mean glandular doses (MGDs) and image quality metrics such as contrast-to-noise ratio (CNR). RESULTS: For all systems and modalities, AEC increased MGD for increasing phantom thicknesses and decreased CNR. The median MGD values (interquartile ranges) were 1.135 mGy (0.772-1.668) for DM, 1.257 mGy (0.971-1.863) for DBT, 1.280 mGy (0.937-1.878) for LE-CEM, and 0.630 mGy (0.397-0.713) for HE-CEM. Medians CNRs were 14.2 (7.8-20.2) for DM, 4.91 (2.58-7.20) for a single projection in DBT, 11.9 (8.0-18.2) for LE-CEM, and 5.2 (3.6-9.2) for HE-CEM. AECs showed high repeatability, with variations lower than 5% for all modes in DM, DBT, and CEM. CONCLUSIONS: The study revealed substantial differences in AEC behavior between systems, modalities, and AEC modes, influenced by technical components and manufacturers' strategies, with potential implications in radiation dose and image quality in clinical settings. RELEVANCE STATEMENT: The study emphasized the central role of automatic exposure control in DM, DBT, and CEM acquisitions and the great variability in dose and image quality among manufacturers and between modalities. Caution is needed when generalizing conclusions about differences across mammography modalities. KEY POINTS: • AEC plays a crucial role in DM, DBT, and CEM. • AEC determines the "optimal" exposure conditions needed to achieve specific image quality. • The study revealed substantial differences in AEC behavior, influenced by differences in technical components and strategies.


Assuntos
Mamografia , Intensificação de Imagem Radiográfica , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Mamografia/métodos , Imagens de Fantasmas
2.
Int J Mol Sci ; 25(7)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38612576

RESUMO

In a recent stereotactic body radiation therapy animal model, radiation pneumonitis and radiation pulmonary fibrosis were observed at around 2 and 6 weeks, respectively. However, the molecular signature of this model remains unclear. This study aimed to examine the molecular characteristics at these two stages using RNA-seq analysis. Transcriptomic profiling revealed distinct transcriptional patterns for each stage. Inflammatory response and immune cell activation were involved in both stages. Cell cycle processes and response to type II interferons were observed during the inflammation stage. Extracellular matrix organization and immunoglobulin production were noted during the fibrosis stage. To investigate the impact of a 10 Gy difference on fibrosis progression, doses of 45, 55, and 65 Gy were tested. A dose of 65 Gy was selected and compared with 75 Gy. The 65 Gy dose induced inflammation and fibrosis as well as the 75 Gy dose, but with reduced lung damage, fewer inflammatory cells, and decreased collagen deposition, particularly during the inflammation stage. Transcriptomic analysis revealed significant overlap, but differences were observed and clarified in Gene Ontology and KEGG pathway analysis, potentially influenced by changes in interferon-gamma-mediated lipid metabolism. This suggests the suitability of 65 Gy for future preclinical basic and pharmaceutical research connected with radiation-induced lung injury.


Assuntos
Lesão Pulmonar , Fibrose Pulmonar , Lesões por Radiação , Animais , Lesão Pulmonar/genética , Fibrose Pulmonar/genética , Inflamação , Interferon gama/genética , Pulmão , Doses de Radiação
3.
J Am Heart Assoc ; 13(8): e033566, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38591342

RESUMO

BACKGROUND: Essential to a patient-centered approach to imaging individuals with chest pain is knowledge of differences in radiation effective dose across imaging modalities. Body mass index (BMI) is an important and underappreciated predictor of effective dose. This study evaluated the impact of BMI on estimated radiation exposure across imaging modalities. METHODS AND RESULTS: This was a retrospective analysis of patients with concern for cardiac ischemia undergoing positron emission tomography (PET)/computed tomography (CT), cadmium zinc telluride single-photon emission CT (SPECT) myocardial perfusion imaging, or coronary CT angiography (CCTA) using state-of-the-art imaging modalities and optimal radiation-sparing protocols. Radiation exposure was calculated across BMI categories based on established cardiac imaging-specific conversion factors. Among 9046 patients (mean±SD age, 64.3±13.1 years; 55% men; mean±SD BMI, 30.6±6.9 kg/m2), 4787 were imaged with PET/CT, 3092 were imaged with SPECT/CT, and 1167 were imaged with CCTA. Median (interquartile range) radiation effective doses were 4.4 (3.9-4.9) mSv for PET/CT, 4.9 (4.0-6.3) mSv for SPECT/CT, and 6.9 (4.0-11.2) mSv for CCTA. Patients at a BMI <20 kg/m2 had similar radiation effective dose with all 3 imaging modalities, whereas those with BMI ≥20 kg/m2 had the lowest effective dose with PET/CT. Radiation effective dose and variability increased dramatically with CCTA as BMI increased, and was 10 times higher in patients with BMI >45 kg/m2 compared with <20 kg/m2 (median, 26.9 versus 2.6 mSv). After multivariable adjustment, PET/CT offered the lowest effective dose, followed by SPECT/CT, and then CCTA (P<0.001). CONCLUSIONS: Although median radiation exposure is modest across state-of-the-art PET/CT, SPECT/CT, and CCTA systems using optimal radiation-sparing protocols, there are significant variations across modalities based on BMI. These data are important for making patient-centered decisions for ischemic testing.


Assuntos
Doença da Artéria Coronariana , Exposição à Radiação , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Índice de Massa Corporal , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos , Doses de Radiação , Exposição à Radiação/efeitos adversos , Dor no Peito , Angiografia Coronária/métodos
5.
BMC Cancer ; 24(1): 437, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594603

RESUMO

BACKGROUND: Soft tissue sarcomas (STS), have significant inter- and intra-tumoral heterogeneity, with poor response to standard neoadjuvant radiotherapy (RT). Achieving a favorable pathologic response (FPR ≥ 95%) from RT is associated with improved patient outcome. Genomic adjusted radiation dose (GARD), a radiation-specific metric that quantifies the expected RT treatment effect as a function of tumor dose and genomics, proposed that STS is significantly underdosed. STS have significant radiomic heterogeneity, where radiomic habitats can delineate regions of intra-tumoral hypoxia and radioresistance. We designed a novel clinical trial, Habitat Escalated Adaptive Therapy (HEAT), utilizing radiomic habitats to identify areas of radioresistance within the tumor and targeting them with GARD-optimized doses, to improve FPR in high-grade STS. METHODS: Phase 2 non-randomized single-arm clinical trial includes non-metastatic, resectable high-grade STS patients. Pre-treatment multiparametric MRIs (mpMRI) delineate three distinct intra-tumoral habitats based on apparent diffusion coefficient (ADC) and dynamic contrast enhanced (DCE) sequences. GARD estimates that simultaneous integrated boost (SIB) doses of 70 and 60 Gy in 25 fractions to the highest and intermediate radioresistant habitats, while the remaining volume receives standard 50 Gy, would lead to a > 3 fold FPR increase to 24%. Pre-treatment CT guided biopsies of each habitat along with clip placement will be performed for pathologic evaluation, future genomic studies, and response assessment. An mpMRI taken between weeks two and three of treatment will be used for biological plan adaptation to account for tumor response, in addition to an mpMRI after the completion of radiotherapy in addition to pathologic response, toxicity, radiomic response, disease control, and survival will be evaluated as secondary endpoints. Furthermore, liquid biopsy will be performed with mpMRI for future ancillary studies. DISCUSSION: This is the first clinical trial to test a novel genomic-based RT dose optimization (GARD) and to utilize radiomic habitats to identify and target radioresistance regions, as a strategy to improve the outcome of RT-treated STS patients. Its success could usher in a new phase in radiation oncology, integrating genomic and radiomic insights into clinical practice and trial designs, and may reveal new radiomic and genomic biomarkers, refining personalized treatment strategies for STS. TRIAL REGISTRATION: NCT05301283. TRIAL STATUS: The trial started recruitment on March 17, 2022.


Assuntos
Temperatura Alta , Sarcoma , Humanos , 60570 , Sarcoma/diagnóstico por imagem , Sarcoma/genética , Sarcoma/radioterapia , Genômica , Doses de Radiação
6.
Radiología (Madr., Ed. impr.) ; 66(2): 107-113, Mar.- Abr. 2024. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-231512

RESUMO

Introducción y objetivos: Comparar las dosis de radiación en las gónadas con y sin protector gonadal y optimizar el uso de estos protectores al realizar radiografías de tórax a lactantes. Materiales y métodos: Se utilizan 2 maniquíes antropomórficos pediátricos, un sistema de rayos X KXO-50SS/DRX-3724HD, y un sistema de radiografía digital CALNEO Smart C12, con y sin protector de gónadas durante la realización de radiografías de tórax. Se coloca un dosímetro cutáneo en tiempo real en el sistema de rayos X y se inserta un dosímetro cutáneo en tiempo real en la cara anterior de la glándula mamaria, en la cara anterior y posterior de la pelvis verdadera, y en los ovarios y testículos. El sistema de rayos X se irradia 15 veces con maniquíes, con y sin el protector de gónadas. Se comparan los valores de las dosis de entrada del paciente medidos por el dosímetro cutáneo en tiempo real para cada maniquí, con y sin el protector de gónadas. Resultados: Los valores medios de las dosis a la entrada del paciente medidos para la cara anterior a nivel de la pelvis verdadera, con y sin el protector, son 10,00 y 5,00μGy en el recién nacido, y 10,00 y 0,00μGy al año, respectivamente. Los valores medios de las dosis a la entrada del paciente medidos para la cara posterior a nivel de la pelvis verdadera con y sin el protector son de 0,00 y 0,00μGy tanto en el recién nacido como al año, respectivamente. Las dosis a la entrada del paciente medidas no se pueden detectar en los ovarios y los testículos ni con el protector ni sin él. No se observan diferencias significativas en los valores de las dosis a la entrada del paciente medidas en la cara anterior y posterior de la pelvis, los ovarios y los testículos en el recién nacido y al año, con y sin el protector (p>0,05).(AU)


Introduction and objectives: To compare gonad doses with and without a gonad protector and to optimize the use of gonadal protectors in infants thorax radiography. Materials and methods: Two pediatric anthropomorphic phantoms are used: an X-ray system for KXO-50SS/DRX-3724HD, and a digital radiography system for CALNEO Smart C12, with and without a gonad protector during infants thorax radiography. A real time skin dosimeter is placed on the X-ray system, and a real time skin dosimeter is inserted on the front side of the mammary gland, the front and back sides of the true pelvis level, and on the ovaries and testes. The X-ray system is irradiated 15 times using phantoms with and without a gonad protector. The measured entrance patient doses values of for the real time skin dosimeter are compared for each phantom, with and without the gonad protector. Results: The medium of measured entrance patient doses values for front side dose of the true pelvis level with and without the protector are 10.00 and 5.00μGy at newborn, and 10.00 and 0.00μGy at one year, respectively. The medium of measured entrance patient doses values for the back side dose of the true pelvis level with and without the protector are 0.00 and 0.00μGy at both newborn one year, respectively. The measured entrance patient doses cannot be detected in the ovaries and testes with or without the protector. No significant differences are observed in the measured entrance patient doses values for the front and back side doses of the pelvis, ovaries, and testes at newborn and one year, with and without the protector (p>0.05). Conclusions: No significant difference was observed in gonad dose measurements with and without the gonad protector during infants chest radiography. We believe that gonadal protector wearing is not necessary.(AU)


Assuntos
Humanos , Masculino , Feminino , Lactente , Gônadas , Radiografia Torácica/métodos , Doses de Radiação , Raios X , Manequins , Radiologia , Radiografia Torácica/efeitos adversos
7.
Sensors (Basel) ; 24(5)2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38474911

RESUMO

This study analyzed radiation dose data to observe the annual decline in ambient radiation doses and assess the factors contributing to fluctuations in reconstructed areas of the Fukushima prefecture. Utilizing a novel mobile monitoring system installed on a community minibus, the study employed a cost-effective sensor, namely, Pocket Geiger which was integrated with a microcontroller and telecommunication system for data transfer, access, visualization, and accumulation. The study area included the region between Okuma and Tomioka towns. The ambient dose rate recorded along the minibus route was depicted on a map, averaged within a 1 × 1 km mesh created with the Quantum Geographic Information System. To ensure accuracy, the shielding factor of the minibus material is determined to adjust the dose readings. A significant decrease (p < 0.001) in the radiation dose ranges from 2022 to 2023 was observed. The land use classification by the Advanced Land Observation Satellite revealed an ecological half-life ranging from 2.41 years to 1 year, suggesting a rapid radiation decay across all land types. This underscores the close connection between radiation attenuation and environmental factors, as well as decontamination efforts across diverse land categories.


Assuntos
Acidente Nuclear de Fukushima , Monitoramento de Radiação , Veículos Automotores , Sistemas de Informação Geográfica , Eletrocardiografia , Japão , Doses de Radiação
8.
Phys Med Biol ; 69(9)2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38537310

RESUMO

Automated assessment of noise level in clinical computed tomography (CT) images is a crucial technique for evaluating and ensuring the quality of these images. There are various factors that can impact CT image noise, such as statistical noise, electronic noise, structure noise, texture noise, artifact noise, etc. In this study, a method was developed to measure the global noise index (GNI) in clinical CT scans due to the fluctuation of x-ray quanta. Initially, a noise map is generated by sliding a 10 × 10 pixel for calculating Hounsfield unit (HU) standard deviation and the noise map is further combined with the gradient magnitude map. By employing Boolean operation, pixels with high gradients are excluded from the noise histogram generated with the noise map. By comparing the shape of the noise histogram from this method with Christianson's tissue-type global noise measurement algorithm, it was observed that the noise histogram computed in anthropomorphic phantoms had a similar shape with a close GNI value. In patient CT images, excluding the HU deviation due the structure change demonstrated to have consistent GNI values across the entire CT scan range with high heterogeneous tissue compared to the GNI values using Christianson's tissue-type method. The proposed GNI was evaluated in phantom scans and was found to be capable of comparing scan protocols between different scanners. The variation of GNI when using different reconstruction kernels in clinical CT images demonstrated a similar relationship between noise level and kernel sharpness as observed in uniform phantom: sharper kernel resulted in noisier images. This indicated that GNI was a suitable index for estimating the noise level in clinical CT images with either a smooth or grainy appearance. The study's results suggested that the algorithm can be effectively utilized to screen the noise level for a better CT image quality control.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Controle de Qualidade , Artefatos , Doses de Radiação , Processamento de Imagem Assistida por Computador/métodos
9.
Korean J Radiol ; 25(4): 384-394, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38528696

RESUMO

OBJECTIVE: To evaluate the image quality of novel dark-blood computed tomography angiography (CTA) imaging combined with deep learning reconstruction (DLR) compared to delayed-phase CTA images with hybrid iterative reconstruction (HIR), to visualize the cervical artery wall in patients with Takayasu arteritis (TAK). MATERIALS AND METHODS: This prospective study continuously recruited 53 patients with TAK (mean age: 33.8 ± 10.2 years; 49 females) between January and July 2022 who underwent head-neck CTA scans. The arterial- and delayed-phase images were reconstructed using HIR and DLR. Subtracted images of the arterial-phase from the delayed-phase were then added to the original delayed-phase using a denoising filter to generate the final-dark-blood images. Qualitative image quality scores and quantitative parameters were obtained and compared among the three groups of images: Delayed-HIR, Dark-blood-HIR, and Dark-blood-DLR. RESULTS: Compared to Delayed-HIR, Dark-blood-HIR images demonstrated higher qualitative scores in terms of vascular wall visualization and diagnostic confidence index (all P < 0.001). These qualitative scores further improved after applying DLR (Dark-blood-DLR compared to Dark-blood-HIR, all P < 0.001). Dark-blood DLR also showed higher scores for overall image noise than Dark-blood-HIR (P < 0.001). In the quantitative analysis, the contrast-to-noise ratio (CNR) values between the vessel wall and lumen for the bilateral common carotid arteries and brachiocephalic trunk were significantly higher on Dark-blood-HIR images than on Delayed-HIR images (all P < 0.05). The CNR values were significantly higher for Dark-blood-DLR than for Dark-blood-HIR in all cervical arteries (all P < 0.001). CONCLUSION: Compared with Delayed-HIR CTA, the dark-blood method combined with DLR improved CTA image quality and enhanced visualization of the cervical artery wall in patients with TAK.


Assuntos
Aprendizado Profundo , Arterite de Takayasu , Feminino , Humanos , Adulto Jovem , Adulto , Angiografia por Tomografia Computadorizada/métodos , Arterite de Takayasu/diagnóstico por imagem , Estudos Prospectivos , Artérias , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Doses de Radiação
10.
Radiol Clin North Am ; 62(3): 371-383, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38553175

RESUMO

This review describes current state-of-the-art computed tomography technology required to address human-physiology-based challenges unique to angiographic imaging. Challenges are based on the need to image a bolus of contrast agent traversing inside rapidly moving structures. This article reviews the latest methods to optimize contrast timing and minimize motion.


Assuntos
Angiografia por Tomografia Computadorizada , Doença da Artéria Coronariana , Humanos , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Doses de Radiação
11.
Appl Radiat Isot ; 208: 111300, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38531242

RESUMO

In this study, Ibandronate as a third generation of bisphosphonates was labeled with rhenium-188 radionuclide. Production and quality control of 188Re-IBA radiopharmaceutical was investigated. The radiation absorbed dose of this radiopharmaceutical was evaluated for adult male based on biodistribution data in mice using the RADAR and Sparks and Aydogan methodologies. The 188Re-IBA was produced with more than 96% radiochemical purity. The highest value of %ID/g was related to bone with 7.11% at 12 h post-injection. About 48% of injected activity was cumulated on the surface of bone tissue 48 h post-injection. The imaging studies confirmed the biodistribution pattern. Radiation absorbed doses of red bone marrow and osteogenic cells were estimated to about 0.39 and 0.71 mGy MBq-1, respectively. The maximum administrated activity was obtained 73.1 MBq kg-1 (2.0 mCi kg-1) of body weight. Effective dose was evaluated about 0.09 mSv MBq-1. The results were compared with other clinically used bone pain palliation radiopharmaceuticals. It was concluded that the 188Re-IBA radiopharmaceutical has a great tendency to be absorbed in bone tissue and it can provide sufficient care for bone marrow ablation with low undesired dose to other normal organs.


Assuntos
Medula Óssea , Compostos Radiofarmacêuticos , Masculino , Camundongos , Animais , Compostos Radiofarmacêuticos/uso terapêutico , Distribuição Tecidual , Doses de Radiação , Osso e Ossos/diagnóstico por imagem
12.
J Radiol Prot ; 44(2)2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38507787

RESUMO

The manipulation of unsealed radiopharmaceuticals by healthcare workers can cause accidental personal contamination leading to occupational radiation skin dose. The UK Ionising Radiations Regulations 2017 require that potential skin doses arising from reasonably foreseeable accident scenarios are included in risk assessments. Workers must be designated as classified if these dose estimates exceed 150 mSv equivalent dose averaged over 1 cm2. Updates from the UK Health and Safety Executive recently prompted many in the UK to review the classification of workers in Nuclear Medicine. Skin dose from contamination cannot be measured, it must be estimated. Varskin+ is a code that is widely recommended for estimating skin dose. The subjective choices made by users when defining modelled scenarios in Varskin+ lead to significant variation in the calculated skin doses. At the time of writing there is no definitive calculation method and all calculations rely on theoretical models. NHS Health Boards in Scotland have adopted a standardised framework for performing skin dose estimates for risk assessments. The parametric sensitivity of Varskin+ inputs were examined and the available evidence was reviewed. Generic, reasonably forseeable, worst-case accident scenarios were decided upon for: direct skin contamination, glove contamination and needlestick injury. Standardised inputs and assumptions for each scenario were compiled in a protocol that has been adopted by the Scottish Health Boards. The protocol allows for differences in practice between departments, but standardises most inputs. While significant uncertainty remains in the estimated skin doses, this approach reduces variation and enables the comparison of estimated skin doses between departments. The framework facilitates continuous improvement as more evidence is gathered to refine the standardised assumptions. Task by task skin dose estimates were made for workers in Nuclear Medicine in Scotland and many workers were designated classified as a result.


Assuntos
Medicina Nuclear , Exposição Ocupacional , Humanos , Doses de Radiação , Radioisótopos , Pele , Compostos Radiofarmacêuticos
13.
Appl Radiat Isot ; 208: 111283, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38484590

RESUMO

A retrospective analysis of occupational exposure to ionizing radiation from medical uses and industrial uses in the three provinces of Central China from 2000 to 2021 was conducted. The average annual effective dose in medical uses and industrial uses decreased from 2.042 mSv and 2.334 mSv in 2000-2002 to 0.476 mSv and 0.371 mSv in 2021 respectively; the fraction of monitored workers receiving annual dose not exceeding 1 mSv increased from 60.78% and 74.45% in 2000-2002 to 94.20% and 96.85% in 2021 respectively, while receiving annual doses exceeding 20 mSv declined from 1.35% and 1.91% in 2000-2002 to 0.18% and 0.03% in 2021 respectively. The average annual effective dose and NR20 in the period 2000-2021 were relatively high in professional public health institutions (0.955 mSv and 0.004) and hospitals (0.815 mSv and 0.004). In 2021, the average annual effective dose to monitored workers in different occupational categories in medical uses in the three provinces of Central China were in the range of 0.199-0.692 mSv, with interventional radiology received the highest dose and NR20 (0.692 mSv and 0.005); the average annual effective dose ranged from 0.161 to 0.493 mSv in industrial uses, with industrial radiography received the highest dose and NR20 (0.493 mSv and 0.001). Occupational exposure in medical uses and industrial uses declined obviously in Central China, and the groups receiving higher doses are the radiation workers working in hospitals and professional public health institutions, or engaged in interventional radiology, nuclear medicine and industrial radiography, warranting more effective radiation protection measures.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Monitoramento de Radiação , Humanos , Doses de Radiação , Monitoramento de Radiação/métodos , Estudos Retrospectivos , Radiação Ionizante , Exposição Ocupacional/análise , China
14.
Radiol Technol ; 95(3): 167-174, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38479769

RESUMO

PURPOSE: To identify technologist-controlled factors to decrease dose and improve image quality and evaluate their use during computed tomography (CT) kidney stone examinations. METHODS: Online scholarly databases were searched to acquire peer-reviewed, published articles involving methods of optimizing radiation dose during CT. These articles were reviewed, and the technologist-controlled factors identified were protocol selection, patient centering in the bore, and scan length. The author retrospectively reviewed CT kidney stone examinations performed at a free-standing emergency department to evaluate the use of these factors. RESULTS: Technologists consistently chose the correct scan protocol. Reviewed literature was used to determine the acceptable variance for positioning at isocenter and overscanning beyond anatomical landmarks. All patient positioning was off-center in the vertical direction, and in 3 of those examinations, patient positioning was off-center more than the 3 cm threshold. Horizontal off-center positioning was less frequent. All examinations had some amount of overscan, with 73.1% of patients being overscanned more than the determined threshold of 10% of total scan length. DISCUSSION: Accurate labeling of protocols at the console assist technologists in choosing protocols correctly. Technologists were inconsistent with patient centering and scan range. The amount of which images were off-center was consistent with previous research studies, while the amount of overscan was less than that found in previous studies. CONCLUSION: Technologists have an important role in optimizing patient radiation dose. Education and quality assurance could help technologists gain awareness of these factors and use them effectively.


Assuntos
Cálculos Renais , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Cálculos Renais/diagnóstico por imagem
15.
Sci Rep ; 14(1): 6393, 2024 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-38493258

RESUMO

The use of mobile head CT scanners in the neurointensive care unit (NICU) saves time for patients and NICU staff and can reduce transport-related mishaps, but the reduced image quality of previous mobile scanners has prevented their widespread clinical use. This study compares the image quality of SOMATOM On.Site (Siemens Healthineers, Erlangen, Germany), a state-of-the-art mobile head CT scanner, and a conventional 64-slice stationary CT scanner. The study included 40 patients who underwent head scans with both mobile and stationary scanners. Gray and white matter signal and noise were measured at predefined locations on axial slices, and signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were calculated. Artifacts below the cranial calvaria and in the posterior fossa were also measured. In addition, image quality was subjectively assessed by two radiologists in terms of corticomedullary differentiation, subcalvarial space, skull artifacts, and image noise. Quantitative measurements showed significantly higher image quality of the stationary CT scanner in terms of noise, SNR and CNR of gray and white matter. Artifacts measured in the posterior fossa were higher with the mobile CT scanner, but subcalvarial artifacts were comparable. Subjective image quality was rated similarly by two radiologists for both scanners in all domains except image noise, which was better for stationary CT scans. The image quality of the SOMATOM On.Site for brain scans is inferior to that of the conventional stationary scanner, but appears to be adequate for daily use in a clinical setting based on subjective ratings.


Assuntos
Tomografia Computadorizada por Raios X , Substância Branca , Humanos , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/métodos , Cabeça/diagnóstico por imagem , Crânio/diagnóstico por imagem , Doses de Radiação
16.
J Environ Radioact ; 274: 107413, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38484579

RESUMO

This study explores the impact of a simulated radiological dispersal device (RDD) event in an urban area on young adults around 20 years old. The RDD releases radioactive Cs-137 (7.0E+3 Ci), a common industrial sterilization source. The study aims to demonstrate that combining computational codes and epidemiological models can produce valuable data to guide initial actions when confronting a hostile radioactive environment. The HotSpot Health Physics and RESRAD-RDD codes were used in the simulation to evaluate the event's initial phase. The codes were executed together, and the HotSpot output data was input into RESRAD-RDD. Based on simulated radiation dose levels, estimated doses were incorporated into radioepidemiological models proposed by the Committee on Biological Effects of Ionizing Radiation (BEIR V or VII report). Despite limitations, data transfer between the models revealed no discontinuities or antagonisms. Radiation doses were simulated under three exposure conditions and two atmospheric release modes (day or night), suggesting that atmospheric conditions, sex, and exposure routine can strongly influence the perception of radiation impacts. This combination of methods can increase situational awareness and help with decision-making and developing coping strategies.


Assuntos
Monitoramento de Radiação , Liberação Nociva de Radioativos , Adulto Jovem , Humanos , Adulto , Radioisótopos de Césio , Monitoramento de Radiação/métodos , Conscientização , Doses de Radiação
17.
ACS Appl Mater Interfaces ; 16(11): 13453-13465, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38445594

RESUMO

Ionizing radiation has become widely used in medicine, with application in diagnostic techniques, such as computed tomography (CT) and radiation therapy (RT), where X-rays are used to diagnose and treat tumors. The X-rays used in CT and, in particular, in RT can have harmful side effects; hence, an accurate determination of the delivered radiation dose is of utmost importance to minimize any damage to healthy tissues. For this, medical specialists mostly rely on theoretical predictions of the delivered dose or external measurements of the dose. To extend the practical use of ionizing radiation-based medical techniques, such as magnetic resonance imaging (MRI)-guided RT, a more precise measurement of the internal radiation dose internally is required. In this work, a novel approach is presented to measure dose in liquids for potential future in vivo applications. The strategy relies on MRI contrast agents (CAs) that provide a dose-sensitive signal. The demonstrated materials are (citrate-capped) CaF2 nanoparticles (NPs) doped with Eu3+ or Fe2+/Fe3+ ions. Free electrons generated by ionizing radiation allow the reduction of Eu3+, which produces a very small contrast in MRI, to Eu2+, which induces a strong contrast. Oxidative species generated by high-energy X-rays can be measured indirectly using Fe2+ because it oxidizes to Fe3+, increasing the contrast in MRI. Notably, in the results, a strong increase in the proton relaxation rates is observed for the Eu3+-doped NPs at 40 kV. At 6 MV, a significant increase in proton relaxation rates is observed using CaF2 NPs doped with Fe2+/Fe3+ after irradiation. The presented concept shows great promise for use in the clinic to measure in vivo local ionizing radiation dose, as these CAs can be intravenously injected in a saline solution.


Assuntos
Meios de Contraste , Prótons , Raios X , Imageamento por Ressonância Magnética , Doses de Radiação
18.
Sci Rep ; 14(1): 6119, 2024 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-38480827

RESUMO

Non-invasive methods of detecting radiation exposure show promise to improve upon current approaches to biological dosimetry in ease, speed, and accuracy. Here we developed a pipeline that employs Fourier transform infrared (FTIR) spectroscopy in the mid-infrared spectrum to identify a signature of low dose ionizing radiation exposure in mouse ear pinnae over time. Mice exposed to 0.1 to 2 Gy total body irradiation were repeatedly measured by FTIR at the stratum corneum of the ear pinnae. We found significant discriminative power for all doses and time-points out to 90 days after exposure. Classification accuracy was maximized when testing 14 days after exposure (specificity > 0.9 with a sensitivity threshold of 0.9) and dropped by roughly 30% sensitivity at 90 days. Infrared frequencies point towards biological changes in DNA conformation, lipid oxidation and accumulation and shifts in protein secondary structure. Since only hundreds of samples were used to learn the highly discriminative signature, developing human-relevant diagnostic capabilities is likely feasible and this non-invasive procedure points toward rapid, non-invasive, and reagent-free biodosimetry applications at population scales.


Assuntos
Exposição à Radiação , Radiometria , Humanos , Camundongos , Animais , Espectroscopia de Infravermelho com Transformada de Fourier , Análise de Fourier , Radiometria/métodos , Proteínas , Radiação Ionizante , Exposição à Radiação/análise , Doses de Radiação
19.
Sci Rep ; 14(1): 6240, 2024 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-38485712

RESUMO

An updated extension of effective dose was recently introduced, namely relative effective dose ( E r ), incorporating age and sex factors. In this study we extended E r application to a population of about 9000 patients who underwent multiple CT imaging exams, and we compared it with other commonly used radiation protection metrics in terms of their correlation with radiation risk. Using Monte Carlo methods, E r , dose-length-product based effective dose ( E DLP ), organ-dose based effective dose ( E OD ), and organ-dose based risk index ( RI ) were calculated for each patient. Each metric's dependency to RI was assessed in terms of its sensitivity and specificity. E r showed the best sensitivity, specificity, and agreement with RI (R2 = 0.97); while E DLP yielded the lowest specificity and, along with E OD , the lowest sensitivity. Compared to other metrics, E r provided a closer representation of patient and group risk also incorporating age and sex factors within the established framework of effective dose.


Assuntos
Proteção Radiológica , Tomografia Computadorizada por Raios X , Humanos , Doses de Radiação , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Proteção Radiológica/métodos , Método de Monte Carlo
20.
World J Urol ; 42(1): 163, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38488927

RESUMO

INTRODUCTION: Due to the radiation exposure for the urology staff during endourology, our aim was to evaluate the trends of radiation protection in the operation room by endourologists from European centers and to estimate their annual radiation. METHODS: We conducted a multicenter study involving experienced endourologists from different European centers to evaluate whether the protection and threshold doses recommended by the International Commission on Radiation Protection (ICRP) were being followed. A 36-question survey was completed on the use of fluoroscopy and radiation protection. Annual prospective data from chest, extremities, and eye dosimeters were collected during a 4-year period (2017-2020). RESULTS: Ten endourologists participated. Most surgeons use lead aprons and thyroid shield (9/10 and 10/10), while leaded gloves and caps are rarely used (2/10 both). Six out of ten surgeons wear leaded glasses. There is widespread use of personal chest dosimeters under the apron (9/10), and only 5/10 use a wrist or ring dosimeter and 4 use an eye dosimeter. Two endourologists use the ALARA protocol. The use of ultrasound and fluoroscopy during PCNL puncture was reported by 8 surgeons. The mean number of PCNL and URS per year was 30.9 (SD 19.9) and 147 (SD 151.9). The mean chest radiation was 1.35 mSv per year and 0.007 mSv per procedure. Mean radiation exposure per year in the eyes and extremities was 1.63 and 11.5 mSv. CONCLUSIONS: Endourologists did not exceed the threshold doses for radiation exposure to the chest, extremities and lens. Furthermore, the ALARA protocol manages to reduce radiation exposure.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Humanos , Estudos Prospectivos , Exposição Ocupacional/prevenção & controle , Fluoroscopia/efeitos adversos , Exposição à Radiação/prevenção & controle , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...